Advanced Features
Optimized Positioning
LATERAL SHIFT TABLE, ± 8CM
IntelliCenter Auto-Lateral Shift Table is the only standard table that can shift up to ± 8cm laterally (16cm total range) to:
- Assist patient positioning
- Reduce dose
- Improve spatial resolution
MULTI-BOWTIE FILTERS
Multi-Bowtie filter size selection, based on anatomy to be imaged, reduces radiation dose in areas outside the filter’s field of view. When used together with the auto lateral shift table, off-center anatomy can be brought to iso-center and the smallest bow-tie filter utilized.
Patient Comfort
HIGHER DATA SAMPLING RATE
SCENARIA’s higher data sampling rate provides faster anatomic coverage without sacrificing image quality and reduces motion artifacts.
WIDE 75CM GANTRY APERTURE & THIN 88CM GANTRY DEPTH
75cm Aperture combined with 88cm thin-gantry-profile provides greater openness for easier patient access.
550 LBS. TABLE WEIGHT CAPACITY
Higher standard weight capacity to accommodate larger patients up to 250 kg (550 lbs.).
LOW MINIMUM TABLE HEIGHT
46cm (18 in) minimum table height eases access for the elderly and patients transferring from a wheel chair.
Iterative Reconstruction
INTELLI IP AND INTELLI IP ADVANCED
Intelli IP and Intelli IP Advanced are Fujifilm’s latest proprietary processing engines that makes use of adaptive iterative reconstruction processes in both projection and image space. Their use will reduce pixel noise at a given level of mAs as compared to filtered backprojection without Intelli IP/ Intelli IP Advanced.
INTELLI EC PLUS
Fujifilm’s proprietary 3D mA modulation technology, Intelli EC, automatically modulates mA to lower individual patient dose levels depending on patient anatomy and size and considering the level of iterative reconstruction selected. Intelli EC Plus can be set to provide real-time control of mA, to achieve a constant Noise Standard-Deviation in the resulting images.
HIGHER DATA SAMPLING RATE
SCENARIA’s higher data sampling rate provides faster anatomic coverage without sacrificing image quality and reduces motion artifacts.
Lower Dose
REDUCED kV
Four settings support lower kV and dose based on individual patient size.
Lower kV provides lower dose for small and pediatric patients.
REDUCED DOSE FOR CARDIAC CTA
ECG Dose Modulation reduces mA by up to 80% during the cardiac phases of a retrospectively gated exam that are not intended for image reconstruction
DOSE REPORTING AND AWARENESS
Scenaria SE provides both DICOM Dose Structured Report and a Simple Dose Report to satisfy the full range of your IT and physician reading dose reporting needs. And, Scenaria SE includes Dose Check, compliant with NEMA XR-25, to monitor for exam doses that may exceed notice or alert levels
AXIAL SNAP-SHOT IMAGING
Pulses the X-ray “on” only during a phase of the cardiac cycle using prospectively gated step-and-shoot cardiac scanning – reducing radiation dose.